Go to the Settings screen (⚙ icon).
Scroll down to + Add license.
✓ LICENSE CODE window opens.
Type in license code. Press Add.
Capital letters are not necessary.
✓ The license appears under ACTIVITIES/FEATURES.
When you have multiple Activity Licenses, you’ll need to select the desired Activity:
On the Settings Screen, under Activity, select Golf Foundation.
Switch the sensors and the hub on.
Put them in the foam and turn them upside down for 4 seconds, until they start blinking. Go to the Sensors screen (Sensor icon).
On the “4DMotion” would like to find and connect to devices on your local network” window, tap Allow.
On the “4D Motion” Wants to Join Wi-Fi Network “Nucleus …” window, tap on Join.
Tap the + icon.
Tap the START CONNECTING button.
Tap CANCEL PAIRING to stop the process.
On the Sensors Paired screen, tap CONFIRM.
✓ On the Sensors screen, the hub and all sensors are listed.
✓ When you tap on the arrow next to each sensor, the window expands.
Once you’ve paired the sensors, you can connect to them on the Sensor list screen:
Make sure your sensors and the hub are blinking.
Tap the Bluetooth Icon.
Join the Nucleus network.
✓ The Sensor list screen shows the list of sensors. The windows are expandable.
✓ The … Menu items become available.
Tip: You can start the Analysis or Training flows without connected and calibrated sensors. The app will guide you through connecting to the hub’s network and calibrating the sensors (if necessary).
We’ll notify you when a firmware update is necessary. The app version you download contains the firmware, which means that 1) to run a firmware update, you need the newest app version. You can download it from the App Store. 2) You don’t need internet connection to run a firmware update.
Turn on the sensors and the hub.
On the “4D Motion” Wants to Join Wi-Fi Network “Nucleus …” window, tap on Join.
✓ On the Sensors screen, the Sensor list appears with 4 or 8 connected sensors.
On the Sensors screen, tap on the ... menu, and select FIRMWARE UPDATE.
On the FIRMWARE UPDATE screen, tap START.
On the FIRMWARE UPDATE SUCCESSFUL screen, tap FINISH.
Reset the hub after the firmware update: plug it into the charger, then unplug it.
Tap the Bluetooth icon on the Sensor Screen.
Tap the arrow next to each sensor to check the firmware version (SW verification code).
The sensors need to be calibrated before use.
You can calibrate them before starting a capture flow. If you have not calibrated them for over 24 hours and start a capture flow, the app will force the calibration.
If you reset the sensors, the app will force the second calibration (Static).
Before calibrating, place the sensors in the foam, with the LED lights up and facing the same direction.
Tip: If you calibrate fewer than 8 sensors, you can leave gaps in the foam.
Go to the Sensor list screen to start the calibration.
Tap on the … menu.
In the menu list, tap on Sensor calibration.
Sensor calibration consists of 2 parts. All instructions are displayed on-screen.
On the ROTATION CALIBRATION screen, tap on FIND SENSORS.
On the FOUND 3 sensors screen, tap NEXT.
✓ When the countdown finishes, you are redirected to the calibration screen.
Rotate the foam 360° at the horizontal axis.
Turn the foam 90° clockwise. Pause for a second.
Rotate the foam slowly 360° at the horizontal axis.
On the SUCCESSFULLY CALIBRATED screen, tap DONE.
Tips:
Each 360° rotation should last 2–3 seconds.
If you can’t complete calibration after a few rotations, move to an area away from any metal or machines and restart from the Sensors screen.
On the STATIC CALIBRATION screen, tap FIND SENSORS.
On the FOUND 3 sensors screen, tap on the NEXT button.
Tap STOP to terminate calibration.
On the SUCCESSFULLY CALIBRATED screen, tap the DONE button.
First calibration
Make sure that the sensors are at least 4 feet away from (e.g. steel chairs, tables, other furniture) or magnetic (e.g. speakers) objects.
Charging
If the sensors are charged between measurements, the second calibration should be redone after unplugging them from the charger.
Restarting sensors
The calibration values are saved on the sensors, restarting them does not necessitate recalibration.
Repeat this calibration in the following cases:
The avatar’s movement is incorrect even after sensor calibration.
You can’t complete sensor calibration.
⚠
If the sensors are used to measure high impact movement, e.g. hitting or pitching, run an Acceleration Calibration at the start of each day.
Prepare the Sensors
Put the sensors in the foam with LED sides up, and facing the same direction.
The sensors should be sticking out of the foam evenly.
Start with sensors in the foam on a flat, steady surface.
Run the Acceleration Calibration
On the Sensors screen, tap the … menu.
On the ACCELEROMETER CALIBRATION screen, tap NEXT.
On the ACCELEROMETER CALIBRATION screen, tap FIND SENSORS.
On the FOUND 3 SENSORS screen, tap NEXT.
On the CALIBRATION screen, follow the on-screen instructions, and tap NEXT.
Repeat 5 times.
On the SUCCESSFULLY CALIBRATED screen, tap DONE.
Tip: If you start a capture 24 hours after the last Static Calibration or right after sensor reset, the app will guide you through the calibration without having to stop the capture flow.
On the Sensors screen, tap on the … menu.
On the menu list, tap on Static Calibration.
On the STATIC CALIBRATION screen, tap FIND SENSORS.
On the FOUND 8 sensors screen, tap on the NEXT button.
Tap STOP to terminate calibration.
On the SUCCESSFULLY CALIBRATED screen, tap the DONE button.
Tip: If you calibrate fewer than 8 sensors, you can leave gaps.
First calibration
Make sure that the sensors are at least 4 feet away from (e.g. steel chairs, tables, other furniture) or magnetic (e.g. speakers) objects.
Charging
If the sensors are charged between measurements, the Static Calibration should be redone after unplugging them from the charger.
Restarting sensors
The calibration values are saved on the sensors, restarting them does not necessitate recalibration.
Analyse Your Swing
On the Home screen, tap the Analyse Your Swing button.
Connect to the sensors and tap Next.
Tip: If you aren’t connected to the hub's network, on the “4DMotion” Wants to Join Wi-Fi Network “Nucleus …” window, tap on Join.
Optional step: The app may guide you through Sensor calibration if you haven’t performed them within 24 hours yet. Follow the on-screen instructions. For more information, check Sensor Calibration above.
Place the sensors on the hip, chest and left lower arm according to the instructions on-screen.
Tip: Make sure that there’s no metal (e.g. belt buckle, watch) near the sensors, as these can interfere with the sensors.
Place the hub on the left side of the body.
Tip: Tick the Do not show again box if you don’t want to see this instruction next time.
On the stand still in attention pose on the target line screen, read the instructions on the correct position. Please note: remain in the same orientation while making the golf swings.
Select the length of the countdown, tap Next, and stand still in attention pose until the User Pose Calibration is finished.
On the Capture screen, wait for the app to show the “Now you can swing” text to make your first swing.
Wait until the app processes and prompts you to make the next swing or finish the session by pressing the Done button.
Once the session is finished, you’ll see a review of all swings.
You can delete sessions by tapping the Trash bin icon.
You can move on to training the most problematic position by tapping the green Train position button.
On the Home screen, tap Start Training.
Connect to the sensors, and tap the Next button.
Tip: If you aren’t connected to the hub's network, on the “4DMotion” Wants to Join Wi-Fi Network “Nucleus …” window, tap on Join.
The Sensor Placement and User pose calibration flows are the same as above.
Tip: If you have made a swing analysis or a training session, you don’t have to go through the sensor placement and user pose calibration flows again for 1 hour.
Make a swing in the proper form, and stay in each position for 1 second.
Tap the Settings button (⚙ icon) to change the settings.
Auto vs Manual: change between automatic movement detection to manual. On the Manual setting, you have to press the Next button to move on to the next position.
Position time: choose the length of time you need to hold the position for. Only relevant with Auto movement detection.
Audible feedback: select if you’d like to hear audible feedback.
Positions: select which positions should be captured.
Range tolerance level: select the range tolerance.
Body parts: select which body parts should be captured.
Tap the Back button to finish Training.
P0: Address (right before the forearm starts moving into the backswing).
P1: Mid-back swing (forearm is below horizontal, at 45° to the ground from frontal point of view).
P2: Top of swing (forearm transition).
P3: Mid-downswing (forearm is below horizontal, at 45° to the ground from frontal point of view).
P4: Impact (forearm is vertical, pointing to the ground).
P5: Follow through (forearm is below horizontal, at -45° to the ground from frontal point of view).
P6: Finish (chest direction change).
On the Home Screen, tap Show Progress.
On the History screen, you’ll find a list of previous sessions and results.
Select a session by tapping and see the results of each individual swing.
Train the most problematic position by tapping on the green Train Position at the bottom of the screen.
Delete sessions by tapping the Trash bin icon.
Jump to the Analysis flow by tapping on the blue Analyse your Swing button.
Jump on the Training flow by tapping on the green Start Training button.
8. On the Player System tab, you can view your student’s captures made with the 2-sensor Golf Foundation Player version.
If your sensors have shifted in the straps, you should repeat the user pose calibration to ensure accurate captures.
To repeat the User Pose calibration (Attention Pose calibration) on the Home screen
Tick in the Redo user pose calibration checkbox.
Select Analysis or Training.
Complete the User Pose calibration.
To repeat the user pose calibration during Training:
Tap the Sensor icon in the top right corner of the Training screen.
Stand in the attention pose during the 3 sec countdown.
✓The user pose has been reset.
Please note: remain in the same orientation while making the golf swings.
Once you put on the sensors and run a User Pose calibration, you don’t have to repeat the process again within the same session, even if moving from analysis to training, or vice versa.
If you want to repeat sensor placement, go to the Home screen.
Tick in the Redo sensor placement checkbox.
Select Analysis or Training.
Go through the sensor placement flow and the User pose calibration.
Go to the Home screen.
Tap on the Pencil icon next to your name.
Edit the profile data and tap Save.
You can delete your account at any time. Account deletion removes your Personal Information from the app and our server permanently. You won’t be able to log in to your account and access the activities and features of the app, as well as your past motion capture data.
To delete your account, follow these steps:
Go to the Home screen, and select your account.
On the My Profile screen, tap the Pencil icon next to your name.
On the Profile screen, tap Delete account at the bottom of the screen.
Note: You cannot delete Student profiles. Students can delete their own profiles by completing the steps above.
Hardware Manual
Plug the mini USB charger into the sensors and the hub.
Use a wall adapter with min. 1.5A output.
Estimated charging time for sensors: 1h.
Estimated charging time for hub: 2.5h.
Tip: If your charger produces less than 1.5A, the sensors/hub may not charge correctly.
Put the sensors in the foam.
Note: The LED lights should be up, facing the same direction.
Turn the foam upside down for 4 seconds.
Turn them right side up.
✓The sensors are blinking yellow.
Hub
Turn the hub upside down for 4 seconds.
Turn it right side up.
✓The hub is blinking yellow.
Put the sensors and the hub on the charger for 2 seconds.
✓The sensors and the hub are blinking yellow.
When not in use, it is best to either shut off the sensors or plug them into the charger. The system switches off after 15 minutes of inactivity.
On the Sensors screen, tap the … menu.
Select Shut down from the list.
The hub has its own Wi-Fi network called “Nucleus XXXX”. Find the exact name of the network on the bottom of the hub.
On the Sensors screen, tap the Bluetooth icon.
On the “4DMotion” Wants to Join Wi-Fi Network “Nucleus …” window, tap on Join.
✓ On the Sensors screen, the Sensor list appears with the connected sensors.
⚠
When you’re connected to the hub’s network, you aren’t connected to the internet. Switch to your Wi-Fi before you perform the following actions:
Add Licenses.
Add new students.
Watch the video tutorial. If you tap on the Watch Tutorial button, your device will automatically switch back to your Wi-Fi network.
Log out.
Sync your captures to our server.
Send diagnostic information.
Sensor Visibility
All sensors should be in the line of sight of the hub.
The hub should be placed on the side of the player to ensure sensor visibility. Use the clip-on mount to attach the hub to the player’s belt or trouser.
Reset Hub
Plug in and unplug the hub in the following cases:
The hub’s LED starts blinking red-blue-green quickly.
The hub doesn’t connect to your device.
Note: Wait a few seconds before connecting to the hub’s network again.
Keep Hub in Wi-Fi range
Keep the hub in the Wi-Fi range of your device. This is typically within 30 feet, depending on the environment.
Each sensor has an LED light in the bottom right corner. The color of this LED indicates the status of the sensor:
Red blinking: low battery < 10%
Pulsing green light: charging
Green blinking: fully charged
Yellow blinking: active sensor
Yellow blinking twice per second: sensor connected to hub
Green blinking on the hub: active hub
Red blinking on the hub: the hub is streaming data from the sensors to the app
On the Sensors screen, tap the Bluetooth icon to identify the sensors.
✓The sensors light up with identifying colors/patterns:
3 solid colors: red, yellow, green
3 blinking colors: red, yellow, green
2 changing colors: red-green, red-yellow
⚠
Make sure that there aren’t any metal objects in close vicinity to the sensors (e.g. watches, belt buckles, chairs, electronic devices).
After Static Calibration, handle the sensors with care. Don’t shake or drop them. If you do, please recalibrate!
Try to minimize the time between Static Calibration and user pose calibration.
Do not put sensors in the strap and then put them down on the table.
Avoid any excessive movement before the first user pose calibration.
Avoid standing in direct air condition breeze or cross-draft. Temperature changes impact the system negatively (the higher the change, the bigger the impact).
Run the user pose calibration in the same place where you will be taking captures!
Sensor error during firmware update
Please press “Restart” and try again.
After several failed attempts, remove and re-pair the sensors:
On the Sensors screen, tap on each sensor and tap REMOVE.
Tap on the hub and tap REMOVE.
Tap the + icon.
Tap the START CONNECTING button.
On the Sensors Paired screen, tap CONFIRM.
On the … menu, select Firmware Update and start over.
First calibration fails
Don’t rotate too fast. Each rotation should take approx. 3 seconds.
Move away from your current location (e.g. a meter), as there could be too much magnetic disturbance where you are standing right now. The software has certain thresholds within which it tolerates disturbances.
If this calibration keeps failing even after several attempts in several locations, please run an accelerometer calibration, and try again.
Hub timeout or other hub connection error
Reset the hub by plugging it into the charger and unplugging it.
Close and restart the 4D Motion app.
Reconnect to the hub’s network, Nucleus XXXX.
Press the Bluetooth icon. Make sure that the sensors show up on the page and each one is marked with a color.
Bluetooth does not connect to all paired sensors
Make sure you are connected to the Hub’s network (Nucleus XXXX), and that the sensors are awake (blinking yellow). If not, turn the sensors upside down for 4 seconds to turn them on.
Reset the hub by plugging it into the charger for a few seconds, then unplug it.
Restart the application, go to the sensors page, connect to Nucleus XXXX, and tap the Bluetooth button again.
‘Hub response timeout’
During sensor calibration: check if your device is connected to the hub’s network (in iOS Settings). If the hub isn’t available on the Wi-Fi list, charge it for a minimum of 15 seconds and refresh the network list. It may take a few seconds for the hub’s network to show up on the list. Go back to the app, and connect to Nucleus XXXX.
During Static Calibration: check if your device is connected to the hub’s network (in iOS settings). If the hub isn’t available on the list, charge it for a minimum of 15 seconds and refresh the network list. It may take a few seconds for the hub’s network to show up on the list. Go back to the app, and connect to Nucleus XXXX.
When connecting to sensors: First start the flow again using the ‘Connect’ button. If it doesn’t help, check in the iOS Settings menu if the device is connected to the hub’s network. If the hub isn’t available on the list, charge the hub for a minimum of 15 seconds, unplug it, and refresh the network list. It may take a few seconds for the hub’s network to show up on the list. Go back to the app, and connect to Nucleus XXXX.
During sensor placement: Start the flow again using the Next button. If this doesn’t help, please reset the hub: charge it for 5 seconds, then try again.
User Pose Calibration errors
The hub is too far away from the user or your device. ‘Cannot connect to some sensors. Please make sure that your mobile device has direct or at least partial line of sight with each sensor…’
When performing a capture, the hub should be on the student’s body using the belt clip, or within a few feet if not worn using the belt clip. First, try to start the flow again using the Next button. If it doesn’t help, change your position so that the sensors and the hub are in the line of sight of your device.
Hub response timeout: Start the flow again using the Next button. If this doesn’t help, please reset the hub: charge it for 5 seconds, then try again.
Sensor error: First try to start the flow again using the Next button. If it doesn’t help, change your position in front of your device so that the sensors are in the line of sight of your device.
Sensors aren’t blinking
If sensors are active but not connected to the hub for more than 15 minutes, they turn off. Turn the sensor upside down to activate them again. If they don’t start blinking, put them on the charger for at least 10 minutes.
Sensor’s LED is stuck in a solid color (e.g. red), or sensor doesn’t light up after pressing the Bluetooth icon
Reset the sensor by charging it for 5 seconds. Unplug it and press the Bluetooth icon.
Hub isn’t blinking
The hub is switched off (automatically or due to low battery). Your device may not be connected to the hub’s network.
Turn the hub upside down for 4 seconds to wake it up. If that doesn’t help, charge it for a few minutes.
Connect to the Nucleus XXXXX network.
Press the Bluetooth icon on the Sensor list screen to check if the hub can connect to your device, and to see its battery level.
‘Error - No sensors found. Turn on an unpaired sensor and retry.’
The message means there aren’t any available, unpaired sensors nearby. This can happen if A) available sensors have already been paired, or B) the unpaired sensors aren’t available for the hub and the device.
If the sensor doesn’t light up, turn it upside down to activate it. If it doesn’t help, put the sensor on the charger for at least 10 minutes, unplug it and try again.
‘Not all of your sensors are calibrated. Please calibrate before you move on to the next screen.’
Turn the sensors upside down to wake them up.
If that doesn’t help, plug in and unplug all the sensors and the hub.
Make sure your device is connected to the hub’s network.
Start the capture again.
Hub blinks red-green-blue
Plug in and unplug the hub to reset it.
Note: Wait a few seconds before connecting to the hub’s network again.
The visualization is incorrect. E.g. body parts are moving in the wrong direction, or the orientation of the avatar is not right.
If the capture avatar is not moving correctly, make sure the sensors are on the right body part. If you’re unsure about this, you can press “Reconnect sensors” on the Start Capture screen. This starts the sensor placement flow.
You can adjust the sensors if needed, and run a User Pose Calibration. If you need to adjust them because the straps shifted, run a User Pose Calibration again.
If these don’t resolve the issue, you may be in a magnetic environment that confuses the magnetometer in the sensors. Strong magnetic interference can cause the sensors to ‘drift.’ This can result in incorrect visualization, e.g. the body parts are not aligned correctly. You can perform Static Calibration to stop the drift. If you are in an environment with high magnetic interference, you may have to repeat Static Calibrations as time goes by and the sensors drift.
If you’re having visualization errors even after several calibrations, please run an Accelerometer calibration.
Reporting errors and bugs
In the app: go to Settings '⚙', and tap 'send diagnostic info'. This works only when you’re connected to the Internet.
Via email: support@4dmotionsports.com. When reporting errors via email, please always write down what you did step by step, and attach a screenshot or screen recording of the error.